Rentals

ETC Source Four Photometrics

ETC Source Four 90º

Distance (ft) 4.2' 8' 12' 15'
Field Diameter (ft) 8' 15' 23' 28'
Illumination (fc) 642 177 81 50

ETC Source Four 50º

Distance (ft) 10' 15' 20' 25'
Field Diameter (ft) 9.5 14.3 19.0 23.8
Illumination (fc) 349 155 87 56

ETC Source Four 36º

Distance (ft) 25' 30' 35' 40'
Field Diameter (ft) 15.8 18.9 22.1 25.2
Illumination (fc) 131 91 67 51

ETC Source Four 26º

Distance (ft) 40' 45' 50' 55'
Field Diameter (ft) 17.9 20.1 22.4 24.6
Illumination (fc) 99 79 64 53

ETC Source Four 19º

Distance (ft) 45' 55' 65' 75'
Field Diameter (ft) 14.2 17.3 20.5 23.6
Illumination (fc) 14.2 95 68 51

ETC Source Four 14º

Distance (ft) 31' 50' 70' 90'
Field Diameter (ft) 8' 13' 18' 23'
Illumination (fc) 421 162 83 50

ETC Source Four 10º

Distance (ft) 85' 100' 115' 130'
Field Diameter (ft) 16.1 19.0 21.8 24.7
Illumination (fc) 116 84 63 50

ETC Source Four 5º

Distance (ft) 105' 125' 145' 165'
Field Diameter (ft) 12.6 15.0 17.4 19.8
Illumination (fc) 124 88 65 50